We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
Categories

Medical Equipment Lung Function Testing Analyzer YSSPR303

Model: YSSPR303
Standardized prediction value for different ethnic groups.
Built-in bronchial dilation and provocation test modules.
Vivid stimulation animation, good guide and introduction for small age patients.
  • ModelYSSPR303
  • BrandYSENMED
  • PriceGet Price
  • MOQ1
  • Ship FromFrom Guangzhou, China
  • ShippingAny shipping terms convenient for customers
  • -
    +
    Categories:Spirometer
    Share:
    Description Get Price Review


    F
    eatures

    Standardized prediction value for different ethnic groups.

    Built-in bronchial dilation and provocation test modules.

    Vivid stimulation animation, good guide and introduction for small age patients.

    High precision differential pressure flow sensor combines with high efficiency filter can avoid cross

    contamination and give effective protection.

    Conform to ATS and ERS standards.

    More than 100 test parameters, fully meet the daily requirements and academic research requirements.

     

    Indications

    COPD patients or borderline patients. PFT can detect COPD 5-10 years earlier than other methods such as X- ray, blood gas analysis and so on.

    Patients with bronchial asthma, emphysema, chronic bronchitis, pulmonary fibrosis and pneumoconiosis or tuberculosis, require diagnosis and efficacy evaluation.

    Patients with chronic cough.

    Patients with dyspnea or chest tightness.

    Long-term smoking or passive smokers.

    People under a polluted environment (live or work in a dusty environment).

    Patients require general anesthesia surgery, chest surgery and other surgeries (50 years above).

    Patients with symptoms such as cough or phlegm.

    Physical examination.

    Management of patients with bronchiectasis treatment.

    For damage determination and compensation inspection.

     

    Parameters

    Modes: SVC, FVC, MVV, MV

    Measured parameters: >100

    Sensor type: Differential pressure sensor

    Volume range : 0~16 L

    Flow range : 0~16L/s

    Volume accuracy : ±3% or 50 ml

    Flow accuracy : ±5% or 200 ml

    Airway resistance : 0.15 kPa/L/s

    PC communication : USB

    Bronchodilator test : Supported

    Bronchial challenge test : Supported

    Pediatric incentive : Supported

     

    Write down your demand below and we will contact you within 24h!